Recently added item(s)

You have no items in your shopping cart.

EN

Recently added item(s)

You have no items in your shopping cart.

Current sensors

Set Descending Direction

27 item(s)

  • TCC 176

    TCC 176

  • JVO 21 75

    JVO 21 75

    Transformer with cable primary Ø 21 mm - Primaries 50 to 600 A - Class 0.5

  • JVO 12 46

    JVO 12 46

    Transformer with cable primary Ø 12 mm - Primaries 40 to 150 A - Class 0.5

  • JVR [CFG]

    JVR [CFG]

    Transformer with wound primary - Configuration as required

  • JVR 64

    JVR 64

    Transformer with wound primary and M8 pipe - Primaries 5 to 100 A - Class 0.5

  • JVR 75

    JVR 75

    Transformer with wound primary and M8 - M10 pipe - Primaries 5 to 200 A - Class 0.5

  • JVS 39 B

    JVS 39 B

    Transformer with busbar primary 3 x 100 x 10 mm - Primaries 1,500 to 4,000 A - Class 0.2s

  • JVS 40

    JVS 40

    Transformer with busbar primary 100 x 20 mm - Primaries 1,000 to 2,000 A - Class 0.2s

  • JVS 50

    JVS 50

    Transformer with busbar primary 100 x 30 mm - Primaries 1,500 to 4,000 A - Class 0.2s

  • JVS 60

    JVS 60

    Transformer with busbar primary 125 x 60 mm - Primaries 1,000 to 5,000 A - Class 0.2s

  • TCRO 80160

    TCRO 80160

    Split-core transformer with busbar primary 80 x 160 mm - Primaries 1,000 to 5,000A - Class 0.5

  • TCR 10 Sec 1A

    TCR 10 Sec 1A

    Transformer with wound primary - Primaries 5 to 75A - Class 0.5

  • TCR 10 Sec 5A

    TCR 10 Sec 5A

    Transformer with wound primary - Primaries 5 to 150A - Class 0.5

  • TCR 100 Sec 1A

    TCR 100 Sec 1A

    Transformer with busbar primary 125 x 60 mm - Primaries 1000 to 4,000A - Class 0.5

  • TCR 100 Sec 5A

    TCR 100 Sec 5A

    Transformer with busbar primary 125 x 60 mm - Primaries 1,000 to 5,000A - Class 0.5

  • TCR 15 Sec 1A

    TCR 15 Sec 1A

    DIN-rail transformer with wound primary - Primaries 5 to 50A - Class 1

  • TCR 15 Sec 5A

    TCR 15 Sec 5A

    DIN-rail transformer with wound primary - Primaries 5 to 50A - Class 1

  • TCR 21 Sec 1A

    TCR 21 Sec 1A

    Transformer with busbar primary 15 x 10 mm, 20 x 10 mm, 25 x 5 mm and cable Ø 20 mm - Primaries 40 to 250A - Class 0.5

  • TCR 21 Sec 5A

    TCR 21 Sec 5A

    Transformer with busbar primary 15 x 10 mm, 20 x 10 mm, 25 x 5 mm and cable Ø 20 mm - Primaries 40 to 250A - Class 0.5

  • TCR 71 Sec 1A

    TCR 71 Sec 1A

    Transformer with busbar primary 50 x 50 mm, 60 x 37 mm, 80 x 30 mm and cable Ø 63 mm - Primaries 400 to 3,000A - Class 0.5

  • TCR 71 Sec 5A

    TCR 71 Sec 5A

    Transformer with busbar primary 50 x 50 mm, 60 x 37 mm, 80 x 30 mm and cable Ø 63 mm - Primaries 400 to 3,000A - Class 0.5

  • TCR 75 Sec 1A

    TCR 75 Sec 1A

    Transformer with busbar primary 3 x 100 x 10 mm - Primaries 1,500 to 3,000A - Class 0.5

  • TCR 80 Sec 1A

    TCR 80 Sec 1A

    Transformer with busbar primary 100 x 20 mm - Primaries 750 to 2,000A - Class 0.5

  • TCR 80 Sec 5A

    TCR 80 Sec 5A

    Transformer with busbar primary 100 x 30 mm - Primaries 1,500 to 4,000A - Class 0.5

  • TCR 90 Sec 1A

    TCR 90 Sec 1A

    Transformer with busbar primary 100 x 30 mm - Primaries 1,500 to 4,000A - Class 0.5

  • JVR 86

    JVR 86

    Transformer with wound primary and M8 - M26 pipe - Primaries 5 to 200 A - Class 0.5

  • TRI 500

    TRI 500

    Three-phase transformer with cable clamp Ø 50 to 240mm² - Bi-rating primaries 50 to 500A - Class 0.2s

Set Descending Direction

27 item(s)