Very high performance relays with forcibly guided (weld-no-transfer), mechanically linked. Test method according to the standard NF F62-002. 8 changeover contacts, for exceptional application flexibility.
A typical application is check reading of a contact to establish the position of the other contacts in self-monitoring control systems with absolute certainty.
Knurled finish to provide lower ohmic resistance thanks to the multiple electrical connection points:
- Extended electrical life expectancy of the component
- Optimal performance for strongly inductive DC loads and for very low loads, such as in the case of interface signals.
Exceptional breaking capacity for controlling very heavy duty DC loads, also with intensive switching frequency.
Optional magnetic arc blow-out for even higher breaking capacity.
Available nominal voltage from 12 to 220VDC/440VAC.
Facility to adapt the products to meet specific application requirements.
The excellent electrical and mechanical performance of these relays allows them to be used in the most demanding sectors, such as:
- Control and signalling functions in rail transport
- Applications with continuous production processes
- Suitable for use on rolling stock
Compliance with standards
- EN 61810-1, EN 61810-2, EN 61810-7 Electromechanical elementary relays
- EN 60695-2-10 Fire hazard testing
- EN 50082-2 Electromagnetic compatibility
- EN 60529 Degrees of protection provided by enclosures
- EN 60077 Electric equipment for rolling stock - General service conditions and general rules
- EN 61373 Shock and vibration tests, Category 1, Class B
- NF F62-002 (§12.3.10) Weld-no-transfer contacts, test method
- EN 45545-2 Requirements for fire behaviour of materials and components – Product No. EL10 – Requirement R26, V0
- ASTM E162, E662 Standard Test Method for Surface Flammability of Materials, Standard Test Method for Specific Optical Density of Smoke