New T82N analog measurement transducer for RMS AC current compliant with the requirements of the latest product standards
Product for the severest environments such as the nuclear sector
Model: IAR 1210B
Type of measurement: RMS AC current
Transfer curves: linear
Rated current In: direct from 0.5 to 10A
Measurement range: 0...1.3 In
Auxiliary source: 100/√3 to 440Vac 50/60Hz and 24 to 125Vdc
Current output: 0 to 20mA
Voltage output: 0 to 10V
Accuracy class: 0.5%
Response time: 120 ms
Insulation: 2 kV
Ingress protection: IP20
Operating temperature: -10°C to +60°C
Type of mounting: plate-mounted or on socket
Reference standard: EN 60688 of April 2013
Totally configurable when ordering
Related products:
Socket for screw-on front connector, reference: EMBB4005
Symmetrical DIN rail adapter, reference: PDINSYME
Asymmetrical DIN rail adapter, reference: PDINASYM